GUYMASTER Release Notes for version 1.1.0 as of April 1, 2008 ------------------------------------- 1. The Importance Factor for the CAN/CSA-S37-01 and TIA/EIA-222-F standards can now be modified in the Project Properties dialog. 2. A new column showing the Standard to be used was added to the Project and Workspace Manager dialog. For Standard TIA-222-G: ----------------------- 1. Discrete Appurtenances that are grouped together in the GUYMASTER input part will be shown on the same page in the profile drawing. This allows the proper graphical treatment of multi-element appurtenances. 2. The default value for the Ka factor (shielding factor for appurtenances) was changed to 0.6 for new projects. If you are using existing projects, you must set the Ka factor to 0.6, otherwise it may be the previous default of 1.0. 3. An error in the calculation of the Ka factor for transmission line clusters was corrected.